About this item

  • QUALITY OEM COMPONENT – OEM-compatible with Majestic, Monessen, IHP, Lennox, Empire, HHT, Tavis Industries, and Napoleon Empire fireplaces, gas logs, and stoves it offers years of reliable service.
  • BUY WITH CONFIDENCE – Trust in Sit Control OEM superior quality heating replacement components. Each product undergoes rigorous quality checks to ensure peak performance and longevity. So, prioritize your comfort and safety with our reliable OEM Sit Controls solutions.
  • NATURAL GAS MILLIVOLT CONTROL – This Sit-820 Nova Series gas control valve is specifically designed for Natural Gas direct vent applications for optimal performance and compatibility with all major brands.
  • REPLACES MULTIPLE MODELS - Direct Vent Only replacement for model numbers J6845, H6244, RGC1007, 14201, 14512, ensuring a broad range of compatibility.
  • USA BASED - We take pride in distributing our products right here in the United States. We are committed to delivering superior products that ensure performance, reliability, and durability. Additionally, we offer top-tier USA based technical support to assist you with any questions or issues, ensuring you receive the best possible experience with our products.



The
0820618 is a SIT NOVA Natural Gas Millivolt remote ready gas valve. It has a fixed flame non adjustable split-system millivolt control for use in direct vent natural gas fireplaces, stoves, gas log sets, and similar appliances.
This
0820618 Natural Gas control valve is remote ready and can be controlled with a millivolt wall switch or a similar millivolt system. It has a HI/LO burner adjustment with and a manually operated knob.

The Sit Controls Gas valve model 0820618 has the following specifications:

  • Split-system millivolt control natural gas valve for use in direct vent appliances.
  • Fixed burner adjustment with Preset flame height operation
  • Minimum voltage 145mV Coil resistance 2.25±0.5
  • Thermo-Electric Unit Hold-in current less than 10Ma
  • Drop-out current Greater than 4mA with coil resistance 10.2.018± 0.003
  • Gas type: Natural Gas
  • Pressure set-point 3.5” w.c. ± 0.3
  • Thermocouple connection 11/32 ASA-DNC
  • Natural Gas Inlet: 3/8 in. NPT
  • Natural Gas Outlet: 3/8 in. NPT
  • Maximum natural gas inlet pressure: 1/2 PSIG Ambient operating
  • Temperature: 32° to 175° F
  • Maximum @ 1 in. w.c. pressure drop 100,000 BTU per hour Regulation capacity 5,000 to 195,000 BTU AP per hour