Reviewed in the United States on January 11, 2025
Wide resistance range of the 5 terminators1 was 52 Ohms (at least within 5% tol.)1 was 53 Ohms (slightly above 5% tol.)1 was 54 Ohms (above tol.)1 was 58 Ohms1 was open
Tom
Reviewed in the United States on February 9, 2024
Great product, speedy shipping, great description
Kung Phil
Reviewed in the United States on October 22, 2024
These are advertised as having a bandwidth up to 6 GHz. Measurements suing an Agilent E5071C Vector Network Analyzer calibrated with an Agilent 85033E 3.5mm Calibration kit show that the impedance is close to 50-Ohm only at very low frequencies. Above approximately 460 MHz, they are not useful as a termination. All 5 in the bag I received have a similar measured response. I guess the low price should have tempered my expectations. As I look back at the product description, there are other indicators that things might be amiss, In one part they say, "There are total ten pieces of connectors in this set ". While the banner description says, "5pcs Coaxial Terminators ". Similarly, the About this item section says, " The impedance is 50 ohm, and frequency is wide between 0 to 6Ghz." While further down in the images it says, "Frequency: 0~3Ghz". Nope, not even close.
Customer
Reviewed in Canada on August 3, 2022
Good product with swell and arrived on time
John West
Reviewed in the United States on February 9, 2022
Only 4 of the 5 50 Ohm terminators were 50 Ohms. The other one was about 38 Ohms. I have no idea how they did that. But it's useless. The other 4 work fine as long as you only use them for low frequencies. So no, I don't use them with my 6 GHz network analyzer, or even my 3 GHz analyzer. You get what you pay for.
Shaun J Karney
Reviewed in Canada on November 30, 2022
They fit well and are useful if you're not needing a exact reading. I found mine were varying in resistance none of them where the same and not exact 50 Ohms some where high and some where lower as well as one of them changes every time it is connected if you're looking for a exact stable reading you might have to go with a brand that's known for stability and accuracy.
Orest D. from Anthony Mark Enterprises Ltd.
Reviewed in Canada on January 2, 2022
Nothing special word as expected suppressing from output with no reflections back to transceiver. I did not measure resistance though.
Clancy
Reviewed in the United States on April 17, 2022
On time and they worked perfectly
Dr. D. Rossbach
Reviewed in the United States on December 2, 2021
Received these very fast. Checked them on a VNA calibrated with a known good termination from 50MHz to 3GHz. 4 of these exhibited a SWR of 1.04 or less over the full range which makes them indistinguishable from the calibration termination. A DC check with a Fluke 115 showed 4 of them to all be within 1% of 50 ohms. The last one measured 56 ohms at DC and exhibited a SWR rising to as much as 3:1 from 2.1 to 3 GHz. I suspect a manufacturing issue on the anomalous termination. Nonetheless this is a good price for 4 excellent terminations.
Joe H.
Reviewed in the United States on October 16, 2021
Quick
frank1723
Reviewed in the United States on January 9, 2021
Great seller. Would buy from again.
Karym Ronda
Reviewed in Canada on December 4, 2019
Ces termiteurs m'ont servi à fermer des connecteurs qui restent ouverts sur un distributeur d'antenne. Ca permet de consolider le signal sur les connecteurs utilisés. Ca marche très bien