About this item

  • ❥Stormer viscometer is a test instrument used to determine the viscosity of paint and other paints with KU value. This instrument can simultaneously display the KU value, CP (centipoise), g (gram), and room temperature of the measured sample viscosity.
  • ❥This instrument is controlled by a microcomputer. The stirring blade is driven by a special constant speed motor to rotate at a speed of 200r/min.
  • ❥The resistance torque of the stirring blade rotating in the tested sample is converted by the computer to KU value (Krebs K rebs) unit (KU) to produce 200 A logarithmic function of the load required for r/min speed, generally used to express the viscosity for brushing and rolling).
  • ❥The operator only needs to insert the stirring blade into the sample to be tested to the specified depth, and the KU value corresponding to the sample can be directly read from the instrument, CP (centipoise) g (gram).
  • ❥The design basis of this instrument is ASTM-D562 standard and GB9269-88 standard. Please consult customer service regarding the operation and usage of the product.


Technical parameter

*Measuring range: 40.2KU-141.0 KU (KU) value 32g-1099g (load value), 27 cp-5250cp

*Measurement accuracy: 1.5% of full scale

* Measurement repeatability: 1.5% of full scale

*The stirring shaft speed: 200 r/min±1 r/min

*Container capacity: about 500ml

*Input voltage: 220V50HZ

*Power: 10W

Dimensions: 500mm*210mm*180mm(19.7*8.27*7.09in)

Weight: 8.5kg

Test environment:

1. The instrument should be placed on a firm and flat surface away from the interference of strong air currents, strong magnetic fields, strong electric fields, and strong electric pulses.

2. To ensure the safety of the operator, the power socket in the laboratory should be reliably grounded.

3. The temperature in the laboratory should be 23℃±2℃, and the relative humidity should be no more than 75℃.

4. The temperature of the sample should be 23℃±0.2℃.

Matters needing attention

1. There are precision measuring parts in the chassis of this instrument, so handle it with care.

2. This instrument is a special-purpose instrument, if special personnel do not disassemble the outer shell of the instrument, so as not to affect the measurement accuracy of the instrument.

3. When the instrument is temporarily not in use, the lifting handle of the instrument should be kept on the upper limit device, and should not be placed in a lower position, otherwise it may cause inflexible lifting.

4. It should be sent to the relevant metrological supervision department for inspection once a year.