Shopping Cart

Your cart is empty.

Your cart is empty.

Generator Interlock Kit Compatible with ITE, Siemens, Gould and murray150 or 200Amp Panel, 1 1/4 Inch Spacing Between Main Circuit Breaker and Generator Circuit Breaker, Electrical Interlock Kit

Free shipping on orders over $29.99

$16.86

$ 8 .99 $8.99

In Stock

About this item

  • 【Compatible models】 ITE 200A interlock kit suitable for ITE, siemens , gould and murray 150 or 200 main circuit breakers. The separation between the main circuit breaker and the branch circuit breaker is 1 1/4 inches. Before buying, you need to make sure the model and spacing are correct.
  • 【Professional and safe】We specializes in Generator Interlock Kits. We produce high-quality products to provide safety for you and your family. Electricity safety is no smal.
  • 【Application scenarios】 Our kit provides a easy and safe solution when inconvenience caused by unexpected power outages. The interlock kit prevents both mains and generator power supply at the same time, it is used to safely direct generator power to any circuit in your home, while ensuring you can safely use all your household appliances.
  • 【Product includes】 1 interlocking panel, 1 matching drill bit, 3 shoulder screws, 3 hex nuts, 5 reminder labels, 2 fixing straps, and installation and use instructions included.
  • 【Worry-free after-sales】Our products come with a lifetime warranty, if our products fail, just send us an email and we will mail you the new original for free replacement part.



Product Description

Generator Interlock Kit for ITE, gould, murray and siemens 150 or 200 main circuit breakers

主图

1.Before purchase, please see the model of the product and measure the distance between the main circuit breaker and the branch circuit breaker

2.The Generator Interlock Kit prevents the utility and generator from being switched on at the same time

3. In case of power failure, safely introduce the generator current to your home to solve your power troubles


侧边栏

Only qualified personnel can work on the panel box

Amateurs should never open the panel box

Please observe all rules and regulations of the national electrical code

All electrical equipment shall be installed and maintained by qualified personnel

Why choose to use our generator interlock kits?

Solve the trouble of power outage, we are professional

In recent years, extreme weather has occurred frequently. Are you troubled by sudden power outages? The situation has affected tens of thousands of families.

Based on this situation, our generator interlock kit came into being. This kit provides a safe solution when using backup power from ITE, gould, murray and siemens generators. Our ITE-200A Interlock Kit effectively prevents both generator power and utilities from being turned on at the same time. So as to ensure your electricity safety.

  • Ensure electricity safety
  • Easy to install
  • Perfect fit
  • Economic and durable

Interlock Kit Installation Steps

anzhuang

  1. With the power off, place the bottom plate (the one with 3 holes) over the top left breaker and mark the location with a pen in the bottom plate holes.
  2. Remove the panel cover from the circuit breaker panel and drill the three holes marked on the panel cover using the 3/16" drill bit provided.
  3. Insert the screws from the back of the cover plate, install the bottom plate and top plate to the front cover plate of the circuit breaker panel, fix with nuts, make sure there is enough space for the top plate to pull freely.
  4. Combine the zip ties into a loop and install the zip ties around the top circuit breaker in the panel.
  5. Place warning labels in appropriate locations.
  6. As shown, the main breaker is open and the generator breaker is closed and cannot be opened. The interlock is properly installed.
gongzuo

  1. The interlock kit requires manual operation and prevents both utility and generator power from being turned on at the same time by sliding the interlock plate left and right.
  2. In the event of a utility power outage, the main breaker and all other breakers must be turned off, the interlock kit adjusted to the generator breaker, and the generator connection circuit working properly.
  3. Interlock kits allow you to deliver power from the generator to any circuit within the electrical panel. You can know which circuit breakers to close or keep on during a power outage.
  4. This eliminates unsafe generator feedback conditions and prevents damage to electrical equipment during a power outage.

Will
Reviewed in the United States on February 16, 2025
The kit was cheaper than a lot of other options out there. There is some slop in the sliding plate but it does the job. Great stickers too. I would recommend it and buy it again, although hopefully I don’t need to at least at this house.
Customer
Reviewed in the United States on January 19, 2025
THIS ITEM WORKED AS DESCRIBED. IT WAS EASY TO INSTALL. NO ISSUES AS LONG AS YOU ORDER THE CORRECT ONE BASED ON THE MEASURMENTS PROVIDED IN THE DESCRIPTION.
Randy
Reviewed in the United States on July 10, 2024
Worked exactly as supposed to. Measure 3 times, drill once. After you have it all wired up, it’s legal. Does exactly what it’s supposed to.
Professor Frink
Reviewed in the United States on January 24, 2024
Careful installation will yield the best results. This installed perfectly for me, but I took a few minutes to make sure the layout was functional before drilling, and then drilling carefully with increasing bit sizes. It works exactly how you'd expect, but the tolerances are tight.
Mr. Dustin
Reviewed in the United States on July 25, 2023
This is a must-have if you're trying to connect your generator to your home electrical panel safely. The instructions are straight forward to follow but if you're not comfortable with electrical work I would hire an electrician or trained professional to install it.
Richard
Reviewed in Canada on June 7, 2023
Installation facile et ça fonctionne bien
Floyd Gantt
Reviewed in the United States on February 9, 2023
May need to have installed by an electrician when you have the 50AMP Circuit breaker for the Backup Generator. Allows you to use your installed electrical panel in your home. when power is lost turn off the main breakers and when you flip on your Generator's 50 amp circuit it blocks the possibility of turning the main breakers back on while the Generator is providing backup power.
Carolyn
Reviewed in the United States on December 27, 2023
This unit worked but wasn't quite the correct size for my Siemens 200 amp box. It installed easally. Even had the correct drill for the holes. The arm prevented my 50 amp double through to completely open. I had to grind the arm smaller for it to work properly. It works correctly now but frustrating having to modify a new product . That is why I didn't give it a perfect score.
oleg
Reviewed in Canada on December 27, 2023
very good reliable protection
Gilles Breton
Reviewed in Canada on December 16, 2023
très bien
Customer
Reviewed in Canada on January 31, 2023
This is exactly what I needed.
R. Wharton
Reviewed in the United States on January 30, 2023
This interlock kit worked great! It was very easy to install, and everything I needed was in the kit. Great price, too! I did have to grind about 1/16" from the top of the interlock where it hits the main breaker, because it was just a bit too long, but that was not a problem. I'm very happy with this interlock kit, and I know my power company is, too!
Antonio Santos
Reviewed in Canada on October 13, 2022
I had order a more expensive kit from a competitor that just wasn’t designed properly. This kit is perfect, easy to install and functions as described.