Your cart is empty.
Your cart is empty.ELECTRICAL Voltage Range: Line (98 to 132 VAC) @ 60Hz , Ignitor: 5A @ 120 VAC, Cool Blower: 10A, 2 HP, 240 VAC, Heat: 5A, 240 VAC, Inducer Motor: 4A FLA, 8A LRA @ 120 VAC, Gas Valve: 1.5A @ 30 VAC STATUS LED: 1 flash:Ignition failure (after 3tries and start of softlockout). 2 flashes: Pressure switch stuck closed,3 flashes: Pressure switch failed to close, 4 flashes: Limit switch failed open, 5 flashes: Flame present with gas valve output off, Rapid Flashing: Wrong polarity of 120VAC and Neutral compatible with Coleman furnace models starting with DGAA, DGAH, DGAM, DGAT, DLAS and more. For the following models: DGAA056BDTA, DGAA056BDTB, DGAA070BDTA, DGAA070BDTB, DGAA077BDTA, DGAA077BDTB, DGAA090BDTA, DGAA090BDTB | DGAH056BBSA, DGAH056BBSB, DGAH077BBSA, DGAH077BBSB | DGAM056BDE, DGAM075BDD, DGAM075BDE, DGAM056BDF, DGAM075BDF | DGAT056BDD, DGAT056BDE, DGAT056BDF, DGAT070BDD, DGAT070BDE, DGAT070BDF, DGAT075BDD, DGAT075BDE, DGAT075BDF, DGAT090BDD, DGAT090BDE, DGAT090BDF | DLAS056BDE, DLAS056BDF, DLAS056E, DLAS075BDD, DLAS075BDE, DLAS075BDF. Replacement for York, Coleman, Evcon, Luxaire OEM furnace circuit board. Replaces for part numbers: 7956-318P/A, 7956-318P, 7956-319P, 7956-3191, S1-7956-319P, 7990-318, 7990-318P, 7990-318P/A, S1-7990-318P, S1-7990-318P/A, 7990-319, 7990-319P, S1-7990-319P, 7990-320P, 031-01910-000, 031-01932-000, 031-01932-001, 031-01932-002, 1012-956, 1012-83-9561, 1012-956A, ICM2801, CIB7990, 082656. Furnace Control Board is perfect for your York Evcon Coleman 7990-319P. It is compatible with various brands, including Coleman, Luxaire, and YORK. Its Power Source includes LP (Liquefied Petroleum Gas), Gas, and NG (Natural Gas). With a Manufacturer Warranty of 1 years, this Furnace Control Board guarantees quality performance. Its Model is S1-7990-319P. This item is a must-have for your HVAC & Refrigeration: Parts & Accessories.