Shopping Cart

Your cart is empty.

Your cart is empty.

SHYSKY Heavy Duty Low Noise 24V 120W Micro Brushless DC Water Pump DC60G-24120S-1 39ft 1003GPH, DRY RUN Protection, For Cooling Circulation Pressure Sys

Free shipping on orders over $29.99

$109.00

$ 42 .99 $42.99

In Stock

About this item

  • SHYSKY DC60G-24120S-1 Water pump, Inlet & Outlet: Both 3/4'' threaded, with external diameter of appr. 25mm; Max static lift 12 m (~39 ft, in pressure, 0.12MPa or 17.4PSI); Max horizontal flow rate 3800 LPH (~ 63L/Min, also, ~1003GPH). Typical feature is with good lift and flow rate, suitable for some micro/ medium circulation/ pressure/ cooling sys.
  • Brushless DC motor, also known as EC motor; Magnetic Driven (NO DIRECT AC 100-240V POWER CONNECTION, PROHIBITED); Small size but strong; Low consumption & High Efficiency; Long time continuous working with low noise;Safety - no spark, Explosion - proof; Low noise about 40dB.
  • With typical features of low-voltage safety, high power-efficiency, low noise at normal work and supporting long-time continuous reliable running, this pump is widely applied for fountain landscape, medical equipment water cooling circulation, air compressor cooling circulation, PC server water cooling, yacht/ vehicle water cooling, and vavrious other industrial, medical and household water processing systems. Note that pump cannot be self-priming, and it is important to make sure that there exists no dry run (especially for long time) and avoid impurities in the pumping systems.
  • Variety Power: 24V DC electric source, Battery or Solar Panel, etc; Soft Start with Low in-rush current, Especially suitable for Solar SYS who can not provide over-high startup impulse current; Constant power level when powering vol. is over 24VDC yet under 28VDC, quite useful feature in some cases.
  • NEW FEATURE: DRY-RUN PROTECTION feature is integrated now in default. Pump works at rated voltage: When there exists no/ in-sufficient in-flow (or significant air bubble contained), it is DRY RUN scenario and protection will be triggered: Pump will access stop-run-stop-run---cycle, greatly reducing rotation speed. When flow comes sufficiently again, pump will re-access normal run. It greatly alleviates physical friction between rotor and pump body and heat generated, yet, NOT completely eliminates the friction since still running yet at lower pace.



Product Description

DC60G-24120S-1 Micro Brushless DC Water Pump

Dimension and weight 152 x88 x110 mm (~6 x 3.5 x 4.3 inch); appr. 1.5Kg (~3.3lbs)
External diameter of outlet 3/4” thread (M25)
External diameter of inlet 3/4” thread (M25)
Driving mechanism Brush-less, magnetic isolated design
Material of pump shell ABS,PES/SPS/PPS/PA66+30%GF (Optional when customization at MOQ)
Condition of us Support continuously work, submersible or land use (note that pump cannot be not self-priming)
Suitable medium Water, oil, etc (corrosive or special fluids shall be tested in advance.) (Pre-test needed for special liquid)
Max working temperature 100 ~ 120℃(for S/A sub-series)
Power consumption 120W @ 24VDC
Rated voltage 24Vdc
Working voltage range 12Vdc ~ 26Vdc
Max load current 5A @ 24VDC
Max horizontal flow rate 3800L/H @ 24VDC (~1003 G/H)
Max static lift 12M @ 24VDC (for S/A sub-series) (~ 39 ft)
Noise class <40dB, at 1m distance
Waterproof class IP68
DC60G-24120S-1-1

NOTE: Control Box of pump is recommended not to be put under water! Please pay attention. DC60G-24120S-1 model, 24VDC, 120W, 3-phase brushless DC design, soft start. (CANNOT BE SELF-PRIMING; NO DRY WORK) Max. Static lift appr. 12m (~39 ft) @ 24VDC and Max. Horizontal flow rate appr. 3800LPH (~1003GPH) @ 24VDC. High Power, Heavy Duty!

Kindly Note: It is only the whole set of pump that is included, with rated voltage of DC power 24V. NO power supply is offered. About the rectangle-shaped metal box, it is the controlbox (brain) part of the pump product, and it is NOT power adapter. Please be not confused.

NEW FEATUREDRY-RUN PROTECTION feature is added on the pumps design in default. Pump works at rated voltage: When there exists insufficient in-flow or no in-flow (or significant bubble inside the in-flow), pump's DRY-RUN protection will be triggered: Pump will access status of stop-run-stop-run-stop-run---cycle. When in-flow comes sufficiently again, pump will then re-access normal run performance after seconds' latency. -- This DRY-RUN protection is aimed to protect our pump product from DRY RUN for long time in some context, which will physically damage the rotor and pump connection part. Pump could be dead due to long-time DRY RUN. This is a good protection. Yet, DRY-RUN itself is always not good thing.

DC45B-24100S-5

Important Notes about Pump’s use & installation

  • DC 24V power supply. No direct AC power powering or over-voltage powering.
  • If it is AC/DC Power adapter, make sure that it can offer sufficient power to pump: output capacity be 24VDC, 6A or over (24V*6A ~ 144W). Note that Power supply cannot be placed in water or moisty location.
  • Control box part is NOT recommended to be under water, especially at long term work. It’s recommended to be placed off-water/ dry location. Firm waterproof tapes (or even epoxy materials) can be closely sealed on the controlbox part before it is placed under water, to streghten its waterproof class, if really have to. Just for in case.
  • Pump supports continuous long time work with relatively low noise at normal working environment. Land use or submersible installation can be either OK, yet pump cannot be self-priming. Make sure that fluid can actively flow passing through inlet/outlet because pump works via centrifugal force of high-speed rotation of impeller inside (to push/throw in-flow out). No long-time dry work without in-flow, or it may damage the pump (Even though DRY-RUN Protection is equiped.).
DC60G-24120S-1-06

Pump Dimension

DC60G-24120S-1-8

[Wide applications] Low-voltage safety, high power-efficiency, low noise at normal work and supporting long-time continuous reliable running. This pump is widely applied for fountain landscape, medical equipment cooling circulation, air compressor cooling circulation, PC server water cooling, yacht/ vehicle water cooling, or other industrial, medical and household water processing systems. Pump cannot be self-priming, and it is important to make sure that there exists no dry run (especially for long time). Avoid impurities in the pumping systems.

DC60G-24120S-1-07

  • Do NOT throw the pump or install it violently, as it could damage the pump body. Do NOT throw the pump directly through the cable, to avoid damage of cable. When at installation, please do not violently to break the pump’s bracket base part, impacting the external appearance and convenience of installation.
  • FIX the pump somewhere when at work, avoiding its own moving-around due to reaction force when at work, which will result in factual pump's DRY-RUN even under water. Also, if it is a circulation system and water will drop back to the tank, avoid the pump installation directly below the water dripping down, to avoid a lot of air bubbles that flow into.
  • When at installation, especially for long term work, do not place the pump upside down (outlet downwards, or inlet downwards). Do place the pump normally upwards, or at least sideways.
  • Impurities shall be avoided, to avoid blockade of impeller due to impurity accumulcation. When for sea/salt water pumping, avoid crystallization.
  • About power polarity: It is DC head connector in default: DC5.5*2.1 (compatible with DC5.5*2.5), INNER PIN + OUTER -. if naked wire connector, RED/BORWN wire is Positive, BLACK/BLUE wire is Negative. DC 24V.
  • To avoid possible misunderstanding of relevant parameters, here we also say something about flow rate value & max static lift value of pump products:
  • For static lift value, it means the max vertical height of flow column when outlet is connected with external matching hose/tube, working at rated voltage. For max flow rate value, it means the max flow rate of pump at horizontal level, working at rated voltage. The higher the height, the lower the flow; when height reaches lift value, flow rate becomes zero. Note that lift value and spraying/shooting height of pump are completely different. So dear users, please do not be confused by them. Meanwhile, certain deviation of around +-10%~15% is advised to be left when in relevant applications, to leave enough margin.