YWBL-WH YYI-4 Current Detection Sensing Module Overcurrent Relay 7-30V 0-30A DC

Free shipping on orders over $29.99

$9.17

$ 4 .99 $4.99

In Stock

About this item

  • Setting description: Power on, display the measured current; (if the measured current terminal none, the LED digits will pulse); Press for the second time (for over 1s to prevent misoperation), the screen shows: P11, k2 adjusts mode, K3 adjusts function
  • Can turn off the LED display to reduce power consumption. With error calibration function. Can be used to limit the current in the circuit, electrical equipment from damage caused by current.
  • This module can detect the DC current value, control the on-off of the relay according to the limit current set by users. Detection range DC 0-30A with the accuracy of 0.01A.
  • Model: YYI-4; Supply voltage: DC 7-30V; Detection range: DC 0-30A; Accuracy: 0.01A (10mA); Standby current: About 20mA; Weight: Approx. 86g/3.0oz
  • Press for the second time, the screen flashes: 0.05, means the threshold I1 0.05A, K2 increases I1, K3 increases I1; Press for the third time, the screen flashes: 0.10, means the threshold I2 0.1A; K2 increases I2, K3 increases I2; Press for the fourth time, the screen shows the measured current , enters the standby state; Long press K2 or K3 in standby state to fine-tune the error of the measured current



Product Description

GS10835-1
YT

Specification:


Model: YYI-4

Supply voltage: DC 7-30V

Detection range: DC 0-30A

Accuracy: 0.01A (10mA)

Standby current: About 20mA

Weight: Approx. 86g/3.0oz

1

GS10835-2

GS10835-3

1

GS10835-2

GS10835-3

Function description:

P-11: When the measured current > I1 (low limit current), the relay closed; When the measured current < I1, the relay opens;

P-12: When the measured current > I1, the relay closes; Maintain the state until the circuit board power off;

P-21: When the measured current > I2 (high limit current), the relay closes; When the measured current < I1, the relay opens;

P-22: When the measured current > I2, the relay closes; Maintain the state until the circuit board power off;

P-31: When measured < I1, the relay closes; When the current > I2, the relay opens;

P-32: When the measured current < I1, the relay closes; Maintain the state until the circuit board power off;

P-41: When the measured current is between I1 and I2, the relay closes, opens in other cases;

P-42: When the measured current is between I1 and I2, the relay closes; Maintain the state until the circuit board power off;

P-51: When the measured current < I1 or > I2, the relay closes, opens in other cases;

P-52: When the measured current < I1 or > I2, the relay closes; Maintain the state until the circuit board power off.