Shopping Cart

Your cart is empty.

Your cart is empty.

Timer Delay Relay DC12V 20A 240W Programmable Cycle Time Switch LED Digital Display Time Relay Module (Active Output DC12V)

Free shipping on orders over $29.99

$9.99

$ 4 .99 $4.99

In Stock

1.Model:Active Output Dc12v


About this item

  • Supply Voltage: DC12V 20A/240W(Max). Size: 79 X 42 X 26mm. Time ranging from 1 second to 999 hours. Double LED displays.
  • Multi functional version, 9 combinations timing time for choice, you could set the timing mode as your requirement.
  • Reserve external trigger interface: 1. Self provided XH-2.54-2P terminal soldering, convenient to connect the external trigger. 2. Solder the external trigger wire directly to the reserved interface.
  • Trigger method: automatic trigger (default) / manual trigger
  • Time delay relays are used in a variety of scenarios: industrial automation control, electrical equipment protection, communication systems, home appliance control, security systems, lighting systems, air conditioning systems, as well as automotive and industrial equipment, etc.



Product Description

T3231 Time

This time control relay is a active output time control relay, according to the working voltage is divided into DC12V, AC110-220V two specifications, equipped with one way normally open relay, with timer on, timer off, alternate on/off, alternate off/on, cycle on/off and cycle off/on six working modes. Power on automatically triggers timing operation, and disconnection automatically saves the last valid setting.

Support Manual trigger, reserve external trigger interface function, need to add welding connection terminal and external trigger device by yourself.

Technical Parameters

Product Name Time Controller
Working voltage DC12V / AC110~220V
Relay type 1 circuit normally open relay
Timing unit seconds/minutes/hours
Timing range 0-999, minimum measurement unit: 1 second
Cycle switch supported
Delayed startup supported
Delayed shutdown supported
Infinite loop supported
Power off save Supported, only save settings, power on reset restart
Buzzer alarm None
Product Functions Timing, Delaying, Time Cycling & etc.
Limited cycle 1-999 adjustable cycles
Trigger method automatic trigger (default) / manual trigger
External trigger Reserve an external trigger port and install a trigger device yourself
Size and Weight Product size: 79.5 × 42.1 × 26.5mm, Installation hole: 77 × 39.3mm, weight: DC12V: 45g, AC110~220V:55g

active output DC12V

Code Meaning

P0--0: power on timing for Seconds (0-999s).

P0--1: power on timing for Minutes (0-999m).

P0--2: power on timing for Hours (0-999h).

P1--0: power outage timing for Seconds

P1--1: power outage timing for Minutes

P1--2: power outage timing for Hours

P2--ON: power on priority

P2--OFF: power outage priority

active output AC110-220V

Code Meaning

P3--OFF: infinite cycle

P3--N(1~999): alternating N times (Maintain the state of the first power-on trigger program after the end of the alternating program)

P4--ON: auto triggre

P4--OFF: manual trigger (Click the R key to trigger, or you can add a part to trigger yourself)

P5--ON: lock

P5--OFF: unlock

active output circuit diagram

Setting method (P5)

1. Enter the "Code Menu" and press and hold the "S" button for 6 seconds to enter

2. Click the "↑" or "↓" button to adjust parameters

3. Click the "S" key to switch codes

4. Double click the "S" button to enter the time setting

5. Set ON time: Click the "↑" or "↓" button to adjust parameters

6. Switch to Off time setting

7. Set Off time: Click the "↑" or "↓" button to adjust parameters

8. Manual trigger: P4=OFF, that is, in manual trigger mode, click the "R" button to trigger operation

9. Reserved external triggering function, requiring self welding of the connection end and external triggering device

T3231 12V

DC12V Reserve external trigger interface

Connection method 1: Self prepared XH-2.45-2P terminal welding, convenient for external trigger connection

Connection method 2: Weld the external triggering wire directly to the reserved interface

active output DAC220V-2

AC version reserves external triggering interface

Connection method 1: Self prepared XH-2.45-2P terminal welding, convenient for external trigger connection

Connection method 2: Weld the external triggering wire directly to the reserved interface

T3231 Set

Cyclic logic

Cyclic alternating on/off (controlled by P2 on/off priority): On ≠ 0 Off ≠ 0

Delayed startup, maintain power on after startup (not controlled by P2 priority): On=0 Off ≠ 0

Delayed shutdown, maintaining power off after shutdown (not controlled by P2 priority): On ≠ 0 Off=0


Audentes
Reviewed in the United States on September 20, 2024
Model differences in the instructions are NOT what is marked on the device. But aside from that, it is working well, it just took some investigating.
Fred Bloggs
Reviewed in the United States on August 21, 2024
The SazkJere Timer Delay Relay is a programmable time controller designed for various applications requiring timed switching. Here’s a detailed review of its features, advantages, and potential drawbacks:Pros:High Current Capacity:20A Rating: With a maximum current rating of 20 amps, the relay can handle substantial loads, making it suitable for a range of applications including high-power devices and systems.Power Handling:1500W Capacity: The relay can manage up to 1500 watts of power, providing versatility in its use. This makes it capable of controlling various appliances and systems that require time-based operation.Programmable Time Control:Custom Timing: The relay allows for programmable time delays, enabling users to set specific durations for when the relay should turn on or off. This flexibility is useful for applications like automated lighting, heating systems, or other timed control needs.Switch Type Output:Passive Output: The passive switch type output provides straightforward operation, ensuring that the relay can be used in a variety of circuits without adding complexity.DC12V Operation:Low Voltage: Operating at 12V DC makes it compatible with a wide range of low-voltage applications, including automotive and battery-powered systems. This also simplifies integration into existing setups.Versatile Applications:Wide Range of Uses: The timer delay relay can be used in various scenarios, such as in automotive systems, home automation, industrial controls, and more. Its ability to manage time-based switching is valuable in many different contexts.Cons:Limited Voltage Compatibility:DC12V Only: The relay operates exclusively at 12V DC, which may limit its use in systems requiring higher voltages or AC operation. Users needing compatibility with other voltage levels will need to consider alternative options.Complex Programming:Learning Curve: Depending on the design, programming the time delays might involve a learning curve for users unfamiliar with timer relays. Detailed instructions or a user manual might be necessary to fully understand and utilize its features.Physical Size:Space Requirements: Depending on the design and housing of the relay, it may require a significant amount of space in the installation area. Users should ensure that there is adequate space for mounting and connecting the relay.Durability Concerns:Build Quality: The durability of the relay's components is crucial for long-term reliability. Users should check the quality of the construction to ensure it can withstand repeated use and environmental conditions.Lack of Features:Basic Functionality: The relay focuses on basic time delay switching and might lack advanced features such as remote control, programmable schedules, or detailed configuration options found in more sophisticated timers.Overall:The SazkJere Timer Delay Relay is a robust and flexible option for users needing a programmable time controller for various applications. Its high current and power handling capabilities, along with programmable time delays, make it suitable for many timed switching scenarios. While it operates at a fixed 12V DC and may require some familiarity with programming, it provides valuable functionality for automating and controlling systems based on time. Users should ensure that the relay meets their specific voltage and feature requirements, but overall, it offers a practical solution for managing time-based electrical control.
Robert D. Whittenberg
Reviewed in the United States on November 4, 2024
The simplicity, flexibility, and pricing of this device are great.For the switch-type version, the output provides a connection between the output ports but does not provide power. If you want output power, opt for the active output version.
jon smith
Reviewed in the United States on October 27, 2024
when there is a power failure and the power comes back, some devices try to connect to internet before cable modem is back online. these devices give up and never get back.i use this devise to wait 3 minutes before powering on the offending devices. no documentation, but i played with buttions and figured out seconds / minutes / hours, and how to set them . set on or off to zero seconds if you dont want that option.