  • REPLACEMENT FIREPLACE THERMOPILE-compatible with the majority of units. For example water heater, Oven, Fireplace & Stove etc..;
  • SAFETY& ENERGY SAVINGS-0.4 x 0.3 x 0.1 inches; Lengths: 24/36 inches. 2 Size for you to choose. Wire Material: glass fiber wrapping line, metal aluminum envelope, these two lines are high temperature resistance fire line, you can choose according to their own needs, focus on length. Our parts are designed and tested for exact equipment specifications, so they work more efficiently and can result in energy savings over time. A small difference will have huge consequences.Just buy our Thermocoupl;
  • EXTREMELY DURABLE-Internal resistance (25℃), varies with specifications and length between 1,500 mΩ and 4,500 mΩ. Normal working temperature 700-750℃;
  • AFTERMARKET REPLACEMENT PART-The Thermocouple is the device that monitors the fire after start-up;
  • EASY INSTALLATION-Spiral type and two-pole plug-in type, Installs quickly and easily tool-less attachment to propane tanks and cylinders.



Product Description

1
2

Thermopile replacement operation steps:

(1) Close the gas valve, unplug the device power plug, ensure that the device is completely powered off, and cut off the gas supply.

(2) Remove the device panel, find the thermopile assembly, observe its connection method, and remove the thermopile that needs to be replaced.

(3) Install a new thermopile and reconnect the corresponding port.

(4) Restore the gas supply, ensure there is no leakage, start the device, and observe whether the flame is stable.

ss
800x600-1

Thermopiles are suitable for the following models for reference.

Fit models:

Empire DV210,DV215,GWT25,GWT35,and GWT50Q313A1188,1950-001,

1950-53B8073485,G01A-332,G01A-512,Q314,Q324,Q327,Q377,Q379,Q382,E31-12 pilot burners

Replacement part number:

60125501,60J79,60J7901,H5882,R942,R1054,2103-512,1950-001,07151553374,7533113

THERMOPILE'S DETAILS

  • Universal Thermopile, 24'' ,36" long 750 millivolts for use in gas fireplaces.
  • Connecting Type: spiral type and two-pole plug-in type.
  • Internal Resistance (25°C): varies with specifications and length between1,500mΩ and 4,500mΩ.
  • Normal Working Temperature: 700-750°C

PURCHASE CORRECTLY

Before you order,please find the real reason and confirm the right model that you need, you can provide the model and serial number of your water heater for confirmation(you can get these info on the metal data plate located on the side of your heater)or check the part allearance to confirmation.

750mv Thermocouples have long been used in self-powered heaters,deep fryer and hot water equipment. it has been proven in millions of appliances as the contractor's preferred thermopile and are found in many of today's gas fireplaces.


D Jean
Reviewed in Canada on January 1, 2025
Fully installed half the price of instore retailFully operationalThank you
Phillip
Reviewed in Canada on December 7, 2024
Fit with no problem. Works perfectly
Customer
Reviewed in the United States on January 14, 2024
Perfect fit. We now have our romantic bedroom fireplace back in action. Barry White mood is here.
francis maxwell
Reviewed in the United States on March 20, 2023
works well
C.R.
Reviewed in Canada on February 19, 2023
Tested thermopile right out of the package and it could not produce any more then 425mV. Would not drive the fireplace gas valve. Replaced with a competitor (brand name unit) and got the voltage and the operation we were expecting. Sent this unit back for refund.
SoManyFish
Reviewed in Canada on December 2, 2023
This product worked well. I measured the power output at 650 mV which is good.Note: The product description stated the lead is 36 inch but it is only 24 inch.
Customer
Reviewed in the United States on November 4, 2023
The hardest part is getting one’s hand in where the pilot light is inside the fireplace. It required me to cut off the spade terminals to slide the wires through the grommet between the fire box and access space for the control valve. Have small gage wire spade and or connectors on hand
TheBeerBaron
Reviewed in Canada on September 17, 2021
I may have gotten a used one or a bad one unfortunately. :-(. My old thermopile was generating a max of 296mv and would drop below 100 when the switch went on. Hence a bad thermopile. This replacement however once installed only made it to 325mv "ish" and dropped to 105mv approx when on. Not even enough power to start the burner sequence. Certainly no where near the 750mv it's stated to be rated at. I even was patient and let it hit up thoroughly before testing again and still no luck. Will have to return and look for another vendor part.
F. Brewer
Reviewed in the United States on December 8, 2021
Near perfect replacement for gas valve thermopile. Teflon wires and metal shields made for simple installation in my gas fireplace. Properly colored wires.
Customer
Reviewed in the United States on January 30, 2021
Working fine so far in our ventless gas fireplace. Installation was awful but that is the fault of the furnace design, has nothing to do with the thermopile itself.
D. Hanson
Reviewed in the United States on September 27, 2020
I had an issue with my Harman Clarity 828i LP Gas Fireplace Insert not working with wall thermostat and only intermittently working with the manual on switch. This Thermopile fixed the problem. unit is working properly after installing.
skip
Reviewed in the United States on February 11, 2020
I just need a thermopile that would produce its rated voltage to get my hot water heater running, but this thing will not produce enough to light the main burner... It barely makes enough volts to lit the pilot light! Even lighting the pilot is intermittent and it wont do it consistently ,probably because the voltage is borderline minimum for even that task..I dont think I can return it because I had to clip off the spade connectors at the end of wire to feed the line thru my burners door to route it to the outside...If the manufacturer will allow a return I would sure appreciate it , as the item is seriously defective...I will write a followup review if the manufacturer offers a refund and change my rating based on their customer care..
Smee63
Reviewed in the United States on October 19, 2020
I received this in one day. Easy to install, great price, and now my natural gas fireplace is working again.